Echometer 및 Echometer+

볼타이트는 수 십년 동안 유압식 볼트 텐셔닝의 선두자리를 지키고 있습니다. 당사의 텐셔닝 공구는 여러 볼트를 동시에 조이고 풀 수 있는 빠르고 정확하며 안전한 솔루션을 제공합니다.

Specifications    
Physical
  • Width (2.5in/63.5mm)
  • Height (6.5in/165mm)
  • Depth (1.24in/31.5mm)
Weight
  • 0.4kg (with batteries)
Keyboard
  • Membrane switch pad with twelve tactile keys
Operating Temperature
  • 14°F to 140°F (-10°C to 60°C)
Case
  • Extruded aluminium body with nickel-plated aluminium end caps (gasket sealed)
Data Output
  • Bi-directional RS232 serial port
  • Windows® PC interface software
Display
  • 1/8in VGA grayscale display (240 x 160 pixels)
  • Viewable area 2.4 x 1.8in (62 x 45.7mm)
  • EL Backlit (on/off/auto)
Ultrasonic Specifications Measurement
  • Pulse-Echo (standard)
  • Pulse-Echo w/Gate (fine adjust)
Pulser
  • Square wave pulser with adjustable pulse width (spike, thin, wide)
Receiver
  • Manual or Auto Set gain control with 40dB range
Power Source
  • Three Three 1.5V alkaline or 1.2V NiCad AA cells
  • Typically operates for 150 hours on alkaline and 100 hours on NiCad
  • Auto power off if idle 5 minutes
  • Battery status icon
Transducer Types
  • Single element (1 to 10MHz & 1/8"to 1" diameters)
  • Locking quick disconnect "00" LEMO connectors.
  • Standard 10 foot cable
  • Custom transducers and cable lenghts available on request
  • Temperature probe for automatic and temparature compensation

 

Measuring    
Range
  • From 1" to 96" ( 25.4mm to 2435mm) length bolts
Time
  • Nanoseconds
Elongation
  • Change in length (Change in length)
Load
  • Force load applied (pounds kip or kilo newtons kN)
Stress
  • Force per unit area stress (pounds kpsi or mega pascals Mpa)
Strain
  • Percentage strain applied (inches per inch or millimeters per millimeter)
Resolution
  • +/- 0.00001 inches (0.0001 mm)
Velocity Range
  • 0.0492 to 0.3936 in/ms
  • 1250 to 9999 meters/sec
  • Fixed, Single and Two point zero calibration options
  • Select bolt material types from a preset or custom list
Units
  • Imperial and Metric
Display
  • A-Scan: Rectified +/- (half wave view), or RF (full waveform view)
Limits Bar (Alarm Limits)
  • Set Hi & Lo alarm limits for displaying an acceptable tolerance range
  • Repeatability Bar Graph- Bar Graph indicates stability of measurement
Data Logger (Internal)
  • Total of 8,000 readings, multiple bolt groups. Stores both waveform views, nanoseconds, elongation, load, stress and strain for each reading
Memory
  • 16 megabit non-volatile ram
Alarm Limits
  • Set Hi and Lo tolerances with audible beeper, viewable scan bar and visual LEDS)
 

 

Download:
Boltight Echometer Software Version 4.05e (Windows)
Boltight Echometer Software Version 4.05e (MacOSX)

Boltight 제품군

연락하기

사용자 정보 취급 방식에 대한 자세한 내용은 개인 정보 취급 방침을 읽어보시기 바랍니다.

연락해 주셔서 감사합니다!